TROUBLESHOOTING
6
SYMPTOM POTENTIAL SOLUTION
SYMPTOM POTENTIAL SOLUTION
Thermostat turns
heating or cooling
system on too often
or not often enough.
Increase or decrease temperature differential setting as
appropriate to provide the desired performance level. See
Setting Temperature Differential section of this manual.
Thermostat does not
turn on heating or
cooling system.
Check to see if OFF is shown in display. This indicates that the
system is turned off at the thermostat. Move the system selector
switch to the HEAT or COOL position. After the compressor short
cycle protection 5-minute period expires the system should start
within a minutes time.
Compressor protection feature may be in effect due to
compressor short cycle conditions. See Compressor Protection
Feature section for full explanation of this feature.
Heating or cooling system may be malfunctioning. Call
a professional service technician immediately to verify
system operation.
Check thermostat wiring to make sure that the heating and
cooling stages are connected to the correct terminals on the
wiring terminal block. See Installation and Wiring Diagrams
sections of this manual.
Low battery indicator
is shown in thermostat
display.
Replace batteries immediately to maintain proper system
operation. See Low Battery Detection and Replacement section
of this manual.
The room is too
warm or too cold.
See Review Set Temperature section of this manual to verify the
current setpoint and make any modifications that are necessary.
OFF is shown in
thermostat display and
heating or cooling
system will not start.
This indicates that the system is turned off at the thermostat.
The thermostat must be in HEAT or COOL modes of operation to
control the heating or cooling system. Move the system selector
switch to the HEAT or COOL position.
Thermostat display
is blank.
It is possible that the batteries are drained and not providing
power for the thermostat to control the system. Replace
batteries immediately to maintain proper system operation.
See Low Battery Detection and Replacement section of this
manual. If you replace the batteries and the display does not
appear, call a professional service technician to verify
thermostat and system performance.
Thermostat will
not allow me to
program a set point
temperature higher
than 90˚ F (32˚ C).
This is above the normal thermostat temperature setting range
of 45˚ to 90˚ F (7˚ to 32˚ C).
Thermostat will not
allow me to program a
set point temperature
lower than 4F (7˚ C).
This is below the normal thermostat temperature setting range
of 45˚ to 90˚ F (7˚ to 32˚ C).
Thermostat will not
allow me to change
the setpoint.
Fan runs intermittently
or when system is off.
The keypad is locked. Press either the or key and the
backlight key at the same time to unlock.
Fan continues to run
all the time whether
the system is on
or off.
Check that the fan control switch is in the AUTO position. This
will allow the fan to run only when the heating or cooling system
is turned on and running.
Check thermostat wiring to make sure that the fan control
wiring is connected to the correct terminals on the wiring
terminal block. See Installation and Wiring Diagrams sections
of this manual.
LO is shown in the
thermostat display
where the room
temperature is
normally displayed.
HI is shown in the
thermostat display
where the room
temperature is
normally displayed.
The temperature sensed by the thermostat is higher than the
90˚ F (32˚ C) upper limit of the thermostats display range.
The display will return to normal after the sensed temperature
lowers within the 45˚ to 90˚ F (7˚ to 32˚ C) display range. Turn
on the cooling system or use other methods to lower the
temperature accordingly.
This condition could occur from the system being turned off
during an exceptionally warm period or upon installation when
the thermostat has been stored for a long period of time in a
warm vehicle or location prior to being installed. The thermostat
is equipped with a mechanical high temperature safety switch
that will turn off the thermostat should the temperature exceed
99˚ F (37˚ C).
TROUBLESHOOTING
6
cont.
Fan switch is in Recirculate Mode ®.
Thermostat turns on
heating instead of
cooling or cooling
instead of heating.
The temperature sensed by the thermostat is lower than the 45˚ F
(7˚ C) lower limit of the thermostats display range. The display
will return to normal after the sensed temperature rises within
the 45˚ to 9F (7˚ to 32˚ C) display range. If the temperature in
the controlled space seems to be normal, wait for the thermostat
to acclimate to the correct room temperature. If the room seems
to be colder than usual, turn on the heating system to raise the
temperature as needed for comfort within the room.
This condition could occur from the system being turned off
during a cold weather period or upon installation when the
thermostat has been stored for a long period of time in a cold
vehicle or location prior to being installed. The thermostat should
be allowed to warm up prior to installation to allow proper
heating control once installed.